Please use this identifier to cite or link to this item:
http://library.ediindia.ac.in:8181/xmlui//handle/123456789/4081
Title: | Polyethylene Low Density (LDPE)-Autoclave Reactor |
Keywords: | Autoclave Reactor Polyethylene LDPE |
Issue Date: | Jan-1979 |
Publisher: | United Nations Industrial Development Organization |
Abstract: | Ethylene is compressed to a reaction pressure of 1 500 bar, initiated with air or oxygen and passed to an autoclave reactor. This has an L/D ratio of 10/1. Lower conversions of 15-20 percent per pass at residence terms of 30 seconds to 2 minutes. Molecular weight distributions tailored to specific needs are possible. Separation sequence is similar to the tubular reactor apart from the difference that more ethylene is recycled due to the low conversion. |
URI: | http://hdl.handle.net/123456789/4081 |
Appears in Collections: | United Nations Industrial Development Organization |
Files in This Item:
File | Description | Size | Format | |
---|---|---|---|---|
POLYETHYLENE LOW DENSITY (LDPE)-AUTOCLAVE REACTOR.pdf Restricted Access | 1.79 MB | Adobe PDF | View/Open Request a copy |